Section 4: operating instructions, 1 main control panel keypad labels, 2 ecc-50/100 switch functions – Fire-Lite ECC-50/100E Emergency Command Center User Manual

Page 82: Main control panel keypad labels, Ecc-50/100 switch functions

Advertising
background image

82

Emergency Command Center Manual —

P/N LS10001-000FL-E:A 4/10/2013

Section 4: Operating Instructions

4.1 Main Control Panel Keypad Labels

The ECC-50/100 is shipped with slide-in labels installed in the keypad as illustrated in the follow-

ing figure. Blank labels are provided to allow the user to customize the zone and message descrip-

tion. Remove the center piece to access the label slots. Using a small, flat screwdriver, press and

release the small plastic latch located on the left side of the center piece.

  

The top row of labels can

be easily removed by sliding them down through the slots in the middle of the keypad and installed

by sliding them up. The bottom row of labels can be removed by sliding them up through the slots

in the middle of they keypad and installed by sliding them down into position.

4.2 ECC-50/100 Switch Functions

The ECC-50/100 display consists of 38 tactile push-button keys. Pressing one or more of the keys

while the panel is not in alarm will select the corresponding circuit for paging or to generate a man-

ually activated evacuation or drill signal. If the panel is in alarm, pressing a key corresponding to

an activated speaker circuit will turn off the circuit and turn on the Trouble LED.

All Call

Pressing this button activates all speaker circuits (that were not manually deactivated) for broad-

cast. ALL CALL paging from the main console's microphone will override paging/manual activa-

tion operations initiated from the other consoles (ECC-LOC, ECC-RPU, ECC-RM) or from a

FACP (if programmed for priority to do so). If all consoles in the system are programmed for equal

priority then the ALL CALL will only occur when the system is not already in use (“System in

Use” LED is not on, remote console active LED is not on). Refer to the SYSTEM CONTROL but-

Figure 4.1 Keypad Labels

e

c

c

k

y

lb

l.

w

m

f

Remove

Install

Install

Remove

TROUBLE SILENCE

AC POWER

GROUND FAULT

CHARGER FAULT

BATTERY FAULT

DATA BUS FAULT

NAC FAULT

NAC ACTIVE

SYSTEM TROUBLE

AUDIO RISER FAULT

DIST. AMP 1

DIST. AMP 2

DIST. AMP 3

DIST. AMP 4

DIST. AMP 5

DIST. AMP 6

DIST. AMP 7

DIST. AMP 8

REMOTE AMPS

SPEAKER

ZONE 13

SPEAKER

ZONE 14

SPEAKER

ZONE 15

SPEAKER

ZONE 16

SPEAKER

ZONE 17

SPEAKER

ZONE 18

SPEAKER

ZONE 19

SPEAKER

ZONE 20

SPEAKER

ZONE 21

SPEAKER

ZONE 22

SPEAKER

ZONE 23

SPEAKER

ZONE 24

MNS

CONTROL

MESSAGE 1

MESSAGE 2

MESSAGE 3

MESSAGE 4

MESSAGE 5

MESSAGE 6

MESSAGE 7

OK TO PAGE

MICROPHONE
TROUBLE

Advertising
This manual is related to the following products: