3. Measurement Mode
16
3.2 How to Collect Data at Certain Time Intervals [Interval Mode]
Display
Key
Procedure
MENU
(1) Press MENU key.
△
, ▽
SET
(2) Select 2. MEASUREMENT.
Then press SET key.
△
, ▽
SET
(3) Select 2. INTERVAL.
Then press SET key.
△
, ▽
SET
SET
(4) Set the measurement condition
in the same manner as when
configuring Average Mode
measurement (P14).
When the measurement condition is configured, select 7. SET
OK!, and press SET key.
☆
To select the item to be
changed
△
, ▽⇨SET
☆
To change setting value
and YES/NO.
△
, ▽⇨SET
☆
Setting is complete.
7. SET OK! ⇨ SET
(a)
Data at each point is average value.
POINT 1···AVE 1=ΣDATA(N)/N
POINT 2···AVE 1=ΣDATA(N)/N
· · ·
· · ·
POINT N --- AVE H=ΣDATA(N)/N
AVE=(AVE1+AVE2+ -----AVE N)/No. of POINT (N)
MAX=AVE I, MIN=AVE J
AVE1, AVE2, ··· AVE N are stored as a data at each point.
Calculation Result
< MENU >
1. MONITOR
2
. MEASUREMENT
3. DATA OUTPUT
4. MEMORY CLEAR
5. UTILITY
< MEASUREMENT >
1. AVERAGE
2
. INTERVAL
3. FLOW RATE
< INT >
1. S-TIME(S) 01
2. DATA (N) 010
3. INT (min) 060
4. POINTS 024
5. MEMORY YES
6. PRINT YES
7
. SET OK!
How long it takes to finish measuring
INT (min) × No. of POINTS (N)
Time length required to measure at one point
S-TIME (S) × N (No. of Data)
DATA (1) (2) (3)
·······
(N)
DATA (1) (2) (3)
·······
(N)
DATA (1) (2) (3)
·······
(N)
Time interval until the next sampling starts
Interval Time --- INT (min)
[POINT 1]
[POINT 2]
[POINT N]
S-TIME (S)
<Measurement Setting
Screen>