Configuration level – West Control Solutions KS 92-1 Programmer manual User Manual

Page 40

Advertising
background image

Configuration level

Configuration parameters

40

KS 90-1

p / KS 92-1

p

Name

Value range Description

Default

IAda

Block auto tuning (only visible with BlueControl!)

0

0

Released

1

Blocked

IExo

Block extended operating level (only visible with BlueControl!)

0

0

Released

1

Blocked

ILat

Suppression error storage (visible only with BlueControl

®

!)

0

0

No:

error message remain in the error list until

acknowledgement.

1

Yes

alarms are deleted from the error list as soon as

corrected

PTmp

Block temporary programm changes

0

0

Released

1

Blocked

pPre

Block Preset to end and reset

0

0

Released

1

Blocked

pRun

Block Run / Stop

0

0

Released

1

Blocked

pSwi

Block switch-over to controller

0

0

Released

1

Blocked

pCom

Block general p rogram-parameter (b.lo, b.Hi, d.00)

0

0

Released

1

Blocked

Pass

OFF...9999

Password (only visible with BlueControl!)

OFF

IPar

Block parameter level (only visible with BlueControl!)

0

0

Released

1

Blocked

ICnf

Block configuration level (only visible with BlueControl!)

0

0

Released

1

Block

ICal

Block calibration level (only visible with BlueControl!)

0

0

Released

1

Blocked

CDis3

Display 3 controller operating level (only visible with BlueControl!)

2

0

No value / only text

1

Display of value

2

Output value as bargraph

3

Control deviation as bargraph

4

Process value as bargraph

TDis3

2...60

Display 3 display alternation time [s] (only visible with BlueControl!)

10

T.dis3

8 Zeichen

Text display 3

T.InF1

8 Zeichen

Text Inf.1

T.InF2

8 Zeichen

Text Inf.2