3 parameters 48, Temp, Inl.1(inl.2) – West Control Solutions CI 45 User Manual

Page 48: Oul.1 (oul.2), Inh.1 (inh.2), Ouh.1 (ouh.2), T.f1 (t.f2), B.f1 (b.f2), E.tc1(e.tc2), Cnt.d

Advertising
background image

8.3

Parameters

µ The entries marked with this symbol are selectable only with the instrument option fitted.

Function selection Func

Name

Value range Description

tEmP

0...9999

Probe temperature for O

2

-measurement

µ

t.I

0,1...9999

Integrator-Zeitkonstante in Minuten µ

P.I

-1999...9999

Integrator-Offsetµ

Inputs InP.1 and InP.2

µ

Name

Value range Description

InL.1(InL.2)

-1999...9999 Input value of the lower scaling point

Oul.1 (OuL.2)

-1999...9999 Display value of the lower scaling point

InH.1 (InH.2)

-1999...9999 Input value of the upper scaling point

OuH.1 (OuH.2)

-1999...9999 Display value of the upper scaling point

T.F1 (t.F2)

0...999,9

Filter time 1 [s]

B.F1 (b.F2)

0...9999

Filter bandwidth

E.tc1(E.tc2)

OFF, 0...100 external cold junction compensation, range depends on temperature unit

Counter/frequency input

µ

Name

Value range Description

Cnt.d

0,1...9999

Counter divider

Cnt.S

0...9999

Counter start value

Cnt.E

0...9999

Counter end value

Frq.L

0.000...100.0 Lower input value in kHz

Ou.L

-1999...9999 Lower output value in phys. units

Frq.H

0.000...100.0 Upper input value in kHz

Ou.H

-1999...9999 Upper output value in phys. units

Frq.F

0...9999

Filter time constant in s

Limit values Lim1 … Lim 3

Name

Value range Description

L.1

-1999...9999 Lower limit 1 (

L.1< -1999 = off)

H.1

-1999...9999 Upper limit 1 (

H.1< -1999 = off)

HYS.1

0...9999

Hysteresis 1

dEL.1

0...9999

Limit 1 delay

L.2

-1999...9999 Lower limit 2 (

L.2< -1999 = off)

H.2

-1999...9999 Upper limit 2

(

H.2< -1999 = off)

HYS.2

0...9999

Hysteresis 2

dEL.2

0...9999

Limit 2 delay

L.3

-1999...9999 Lower limit 3 (

L.3< -1999 = off)

H.3

-1999...9999 Upper limit 3

(

H.3< -1999 = off)

HYS.3

0...9999

Hysteresis 3

dEL.3

0...9999

Limit 3 delay

g

For resetting the parameters to factory setting (default ),

r section 12.4, 6.17 (page 37)

Parameter setting level

48

Parameters

UNIFLEX CI 45