Chiller Technical Manual 7525355 V1.1.0_04_2013

In

sta

lla

tio

n

Chillers

TurboChill™ Air Cooled and FreeCool

Installation Data

Point Loadings

Air Cooled

Standard Unit Point Loads

L1

(kg)

L2

(kg)

L3

(kg)

L4

(kg)

L5

(kg)

L6

(kg)

L7

(kg)

L8

(kg)

R1

(kg)

R2

(kg)

R3

(kg)

R4

(kg)

R5

(kg)

R6

(kg)

R7

(kg)

R8

(kg)

TCC11R04S-01

705

655

-

-

-

-

-

-

755

725

-

-

-

-

-

-

TCC11R06S-01

645

580

450

-

-

-

-

-

685

630

475

-

-

-

-

-

TCC11R08S-01

605

500

450

415

-

-

-

-

640

535

480

430

-

-

-

-

TCC11R06L-02

675

625

470

-

-

-

-

-

710

675

495

-

-

-

-

-

TCC11R08L-03

630

550

535

475

-

-

-

-

660

580

550

485

-

-

-

-

TCC11R10L-03

710

645

595

545

-

-

-

-

745

675

610

555

-

-

-

-

TCC12R08S-04

660

580

570

500

-

-

-

-

715

655

645

555

-

-

-

-

TCC12R10S-04

745

675

625

570

-

-

-

-

810

755

695

625

-

-

-

-

TCC12R12S-04

840

755

695

635

-

-

-

-

905

835

765

685

-

-

-

-

TCC12R14S-04

805

725

660

585

460

-

-

-

890

845

740

565

460

-

-

-

TCC12R10L-05

755

690

640

585

-

-

-

-

825

775

715

640

-

-

-

-

TCC12R12L-06

925

855

785

700

-

-

-

-

985

925

845

740

-

-

-

-

TCC12R14L-06

885

825

745

645

465

-

-

-

965

935

820

615

465

-

-

-

TCC12R16L-06

810

870

835

755

620

-

-

-

840

925

895

815

645

-

-

-

TCC12R18L-06

735

670

800

780

620

580

-

-

770

710

850

835

655

605

-

-

TCC12R20L-06

790

710

845

850

675

630

-

-

825

755

900

900

705

650

-

-

TCC11X04S-01

705

655

-

-

-

-

-

-

755

725

-

-

-

-

-

-

TCC11X06S-01

645

580

450

-

-

-

-

-

685

630

475

-

-

-

-

-

TCC11X08S-01

605

500

450

415

-

-

-

-

640

535

480

430

-

-

-

-

TCC11X06L-02

675

625

470

-

-

-

-

-

710

675

495

-

-

-

-

-

TCC11X08L-03

630

550

535

475

-

-

-

-

660

580

550

485

-

-

-

-

TCC11X10L-03

710

645

595

545

-

-

-

-

745

675

610

555

-

-

-

-

TCC12X08S-04

660

580

570

500

-

-

-

-

715

655

645

555

-

-

-

-

TCC12X10S-04

745

675

625

570

-

-

-

-

810

755

695

625

-

-

-

-

TCC12X12S-04

840

755

695

635

-

-

-

-

905

835

765

685

-

-

-

-

TCC12X14S-04

805

725

660

585

460

-

-

-

890

845

740

565

460

-

-

-

TCC12X10L-05

755

690

640

585

-

-

-

-

825

775

715

640

-

-

-

-

TCC12X12L-06

925

855

785

700

-

-

-

-

985

925

845

740

-

-

-

-

TCC12X14L-06

885

825

745

645

465

-

-

-

965

935

820

615

465

-

-

-

TCC12X16L-06

810

870

835

755

620

-

-

-

840

925

895

815

645

-

-

-

TCC12X18L-06

735

670

800

780

620

580

-

-

770

710

850

835

655

605

-

-

TCC12X20L-06

790

710

845

850

675

630

-

-

825

755

900

900

705

650

-

-

OPTIONAL EXTENDED DISCHARGE PLENUM

STANDARD DISCHARGE PLENUM

3 PHASE

MAINS

ELECTRICAL

ISOLATOR

FANS

ELECTRICAL

ISOLATOR

EMERGENCY

STOP

DISCHARGE AIR

CP1

CP2

(Optional)

MAINS

CONTROLS

BUSBAR

CHAMBER

8 - 20 DIA MOUNTING HOLES

IN BASE OF UNIT

(OPTIONAL)

PUMPS

ELECTRICAL

ISOLATOR

2100

500

2200

50

50

439

1520

1131

1520

2793

802

50

4890

280

624

1063

3464

L1

L2

R1

R2

L3

R3

L4

R4

2

1

Above refers to standard configurations, contact Airedale for other options.