Chillers turbochill™ air cooled and freecool, Installation data, Point loadings freecool – Airedale TurboChill FreeCool 200kW - 1830kW User Manual

Page 106

Advertising
background image

106

Chiller Technical Manual 7525355 V1.1.0_04_2013

In

st

alla

tio

n

Chillers

TurboChill™ Air Cooled and FreeCool

Installation Data

Point Loadings

Freecool

Standard Unit Point Loads

L1

(kg)

L2

(kg)

L3

(kg)

L4

(kg)

L5

(kg)

L6

(kg)

L7

(kg)

L8

(kg)

R1

(kg)

R2

(kg)

R3

(kg)

R4

(kg)

R5

(kg)

R6

(kg)

R7

(kg)

R8

(kg)

TCF11R06S-07

770

730

615

-

-

-

-

-

840

850

730

-

-

-

-

-

TCF11R08S-07

760

685

660

590

-

-

-

-

785

705

665

595

-

-

-

-

TCF11R06L-11

880

915

745

-

-

-

-

-

890

910

715

-

-

-

-

-

TCF11R08L-08

785

730

720

660

-

-

-

-

795

730

705

635

-

-

-

-

TCF11R10L-10

915

890

870

805

-

-

-

-

925

885

845

780

-

-

-

-

TCF12R08S-09

795

725

715

650

-

-

-

-

835

780

770

680

-

-

-

-

TCF12R10S-05

950

920

905

830

-

-

-

-

990

965

930

845

-

-

-

-

TCF12R12S-05

1085

1045

1020

940

-

-

-

-

1135

1095

1055

960

-

-

-

-

TCF12R14S-05

950

995

985

930

755

-

-

-

1035

1085

1020

860

720

-

-

-

TCF12R12L-12

1195

1180

1155

1045

-

-

-

-

1240

1225

1185

1060

-

-

-

-

TCF12R14L-12

1035

1130

1125

1045

800

-

-

-

1115

1205

1140

950

750

-

-

-

TCF12R16L-12

975

1195

1245

1220

1005

-

-

-

1005

1215

1250

1205

980

-

-

-

TCF12R18L-13

895

825

1135

1225

1170

910

-

-

925

870

1125

1180

1075

875

-

-

TCF12R20L-13

960

885

1205

1345

1280

995

-

-

995

930

1200

1295

1170

950

-

-

TCF11X06S-07

770

730

615

-

-

-

-

-

840

850

730

-

-

-

-

-

TCF11X08S-07

760

685

660

590

-

-

-

-

785

705

665

595

-

-

-

-

TCF11X06L-11

880

915

745

-

-

-

-

-

890

910

715

-

-

-

-

-

TCF11X08L-08

785

730

720

660

-

-

-

-

795

730

705

635

-

-

-

-

TCF11X10L-10

915

890

870

805

-

-

-

-

925

885

845

780

-

-

-

-

TCF12X08S-09

795

725

715

650

-

-

-

-

835

780

770

680

-

-

-

-

TCF12X10S-05

950

920

905

830

-

-

-

-

990

965

930

845

-

-

-

-

TCF12X12S-05

1085

1045

1020

940

-

-

-

-

1135

1095

1055

960

-

-

-

-

TCF12X14S-05

950

995

985

930

755

-

-

-

1035

1085

1020

860

720

-

-

-

TCF12X12L-12

1195

1180

1155

1045

-

-

-

-

1240

1225

1185

1060

-

-

-

-

TCF12X14L-12

1035

1130

1125

1045

800

-

-

-

1115

1205

1140

950

750

-

-

-

TCF12X16L-12

975

1195

1245

1220

1005

-

-

-

1005

1215

1250

1205

980

-

-

-

TCF12X18L-13

895

825

1135

1225

1170

910

-

-

925

870

1125

1180

1075

875

-

-

TCF12X20L-13

960

885

1205

1345

1280

995

-

-

995

930

1200

1295

1170

950

-

-

OPTIONAL EXTENDED DISCHARGE PLENUM

STANDARD DISCHARGE PLENUM

3 PHASE

MAINS

ELECTRICAL

ISOLATOR

FANS

ELECTRICAL

ISOLATOR

EMERGENCY

STOP

DISCHARGE AIR

CP1

CP2

(Optional)

MAINS

CONTROLS

BUSBAR

CHAMBER

8 - 20 DIA MOUNTING HOLES

IN BASE OF UNIT

(OPTIONAL)

PUMPS

ELECTRICAL

ISOLATOR

2100

500

2200

50

50

439

1520

1131

1520

2793

802

50

4890

280

624

1063

3464

L1

L2

R1

R2

L3

R3

L4

R4

2

1

Above refers to standard configurations, contact Airedale for other options.