HP StorageWorks XP Remote Web Console Software User Manual

Page 174

Advertising
background image

Table 49 Analyzing the Currency of TrueCopy for Mainframe Sync R-VOLs (continued)

Currency of R-VOL

Fence Level

Status of R-VOL

Current. This R-VOL is synchronized
with its M-VOL.

Data

Suspended - all other types

Suspect. This R-VOL is not synchronized
with its M-VOL if any write I/Os were
issued to the M-VOL after the pair was
suspended. Restore the consistency of
this R-VOL and update it, if required.
The system time stamp information
transferred through ERC or the time of
suspension indicated on the Detailed
Information dialog box will help to
determine the last time this R-VOL was
updated.

Status

Never

Analyzing the Consistency of TrueCopy for Mainframe Async R-VOLs

“Analyzing the Consistency of TrueCopy for Mainframe Async R-VOLs” (page 175)

shows how to

determine the consistency of a TrueCopy for Mainframe Asynchronous R-VOL based on its pair
status and consistency status. For TrueCopy for Mainframe Asynchronous R-VOLs with a consistency
status of Volume, the volume is not consistent with other volumes in the same group, and further
analysis will be required to determine the currency of each of these R-VOLs. The currency of these
R-VOLs can be determined by using the sense information transferred via the ERC or by comparing
the contents of the R-VOL with other files which are confirmed to be current (for example, DB2 log
files). These R-VOLs should be recovered using the files which are confirmed to be current.