Table 54 Troubleshooting Suspended TrueCopy for Mainframe Pairs

Corrective Action

Description

Applies to

Suspend Type

Resynchronize the pair from
the MCU (Resume Pair).

The user suspended the pair
from the MCU using the
M-VOL Failure for Suspend
Kind option. The R-VOL
suspend type is by MCU.

M-VOL

M-VOL by Operator

Resynchronize the pair from
the MCU (Resume Pair).

The user suspended the pair
from the MCU or RCU using
the R-VOL for Suspend
Kindoption.

M-VOL, R-VOL

R-VOL by Operator

Resynchronize the pair from
the MCU (Resume Pair).

The RCU received a request
from the MCU to suspend
the pair. The M-VOL suspend
type is M-VOL by Operator
or R-VOL by Operator.

R-VOL

by MCU

Clear the error condition at
the RCU or R VOL, and then,
resynchronize the pair from
the MCU (Resume Pair).

If you need to access the R
VOL to clear the error
conditions, release the pair
from the RCU (Delete Pair).
After you clear the error
conditions from R VOL,
restart the pair (Add Pair).

The MCU detected an error
condition at the RCU which
caused the MCU to suspend
the pair. The R-VOL suspend
type is R-VOL Failure.

M-VOL

by RCU

Release the pair from the
MCU (Delete Pair), and then
restart the pair (Add Pair).
You should use the Entire
Volume initial copy option
to resynchronize the pair.
You can use the None initial
copy option only if no data
on the M-VOL or R-VOL
changed.

The MCU detected that the
R-VOL status changed to
simplex because the user
released the pair from the
RCU. The pair cannot be
resynchronized because the
R-VOL does not have the
suspended status.

M-VOL

Delete Pair to RCU

Check the path status on the
RCU Status dialog box (see

“ Troubleshooting RCU Path
Status Problems” (page 181)

).

If errors occur on the path,
clear the error conditions.

Clear any error conditions
at the RCU or R VOL.

After you clear the error
conditions, resynchronize the
pair from the MCU (Resume
Pair).

If you need to access the R
VOL to clear the error
conditions, release the pair
from the RCU (Delete Pair).
After you clear the error
conditions from R VOL,
restart the pair (Add Pair).

The MCU detected an error
during communication with
the RCU or an I/O error
during update copy. In this
case, the suspend type for
the R-VOL is usually R-VOL
Failure
.

M-VOL, R-VOL

R-VOL Failure