Table 9 Suspend Types (continued)

Description

Applies to

Suspend Type

The MCU detected an error condition
at the RCU which caused the MCU to
suspend the TrueCopy for Mainframe
pair. The R-VOL suspend type is by
MCU
.

M-VOL

by RCU

The MCU detected that the R-VOL status
changed to simplex because the user
released the pair from the RCU. The
pair cannot be resynchronized because
the R-VOL does not have the suspended
status.

M-VOL

Release Pair to RCU

The MCU detected an error during
communication with the RCU or an I/O
error during update copy. In this case,
the R-VOL suspend type is usually by
MCU
.

M-VOL

R-VOL Failure

The MCU could not find valid control
information in its nonvolatile memory
during the IMPL procedure. This
condition occurs only if the MCU is
completely without power for more than
48 hours (for example, power failure
and fully discharged backup batteries).

M-VOL, R-VOL

MCU IMPL

The pair was suspended before the
initial copy operation was complete.
The data on the R-VOL is not identical
to the data on the M-VOL.

M-VOL, R-VOL

Initial Copy failed

The pair was suspended by the
CGROUP/FREEZE TSO command.

M-VOL, R-VOL (TrueCopy for
Mainframe Sync only)

by FREEZE

The RCU received a request from the
MCU to suspend the R-VOL due to MCU
power-off. The RCU stops expecting
recordsets from that MCU.

R-VOL (TrueCopy for Mainframe
Asynchronous only)

MCU P/S-OFF

The amount of sidefile exceeds the
specified “current pending update data
rate”, and the RCU data is not
transferred within the specified
offloading timer.

M-VOL, R-VOL (TrueCopy for
Mainframe Asynchronous only)

by sidefile overflow