Create pairs – HP StorageWorks XP Remote Web Console Software User Manual

Page 230

Advertising
background image

Get pair status

Select pair devices

Create Pairs

The CreateHrcPair command allows you to establish new TrueCopy for Mainframe pairs.
The CreateHrcPair command only creates the pair. You must run the StartHrcPair command after
establishing the pair to start the remote copy process.
The CreateHrcPair parameters are:

CreateHrcPair $Dev= M VOL device list
,$RcuSn= Serial number list
,$RcuSsid= SSID number list
,$Rdev= R VOL device list
[,$CopyPace= Initial copy pace list]
[,$CopyMode= Initial copy mode list]
[,$Sync= Sync level list]
[,$CTG= CT group list]
[,$Priority= Priority list]
[,$Fence= Fence level list]
[,$OptCfw= CFW flag list]
[,$OptSusDfwBlk= DFW flag list]
[,$OptErrLv= Error level list]
[,$TimeSave= Time-Saving Mode flag]
[,$Diff= Differential management measurement flag list]
[,$TimeStamp= Time stamp transfer list]

The Details for the arguments are:

M-VOL device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#,
VV=vol# within CU.

Serial number list (string): RCU serial number (serial number is five digits decimal 0-9). Do not
specify more than 12 RCUs.

SSID number list (numeric): RCU SSID (four digits hexadecimal).

R-VOL device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#,
VV=vol# within CU.

When you write M-VOL device list or R-VOL device list, you can omit LDKC# if the LDKC# is 0.
For example, you can write 0x0102 when LDKC# is 0, CU# is 1, and vol# is 2.

Initial copy pace list (string): “CP_MIDDLE” = 3 tracks; “CP_FAST” = 15 tracks; default =
CP_FAST.

Initial copy mode list (string): “E” = entire volume; “N” = none; default = E.

Sync level list (string): “S0” or “Synchronous0” = sync, “S2” or “Synchronous2” = async;
default = S0. S0 and S2 cannot be specified at the same time.

CT group list (numeric): consistency group number (0x00 - 0x7F). For async pairs you must
specify this parameter. For sync pairs you must omit this parameter.

Priority list (numeric): priority of initial copy operation (1-256); default = 32.

Fence level list (string): “N” or “Never” = never; “S” or “Status” = status; “D” or “Data” =
data; default = “Never”. For async pairs you must either specify N (never) or omit this
parameter.