Trouble-shooting – ARRI LOCPRO 35 User Manual

Page 56

Advertising
background image

56

Fault

Cause

Remedy

Mains “ON” without function

Mains voltage failure?

Connect to another electrical socket

unit will not operate

and check.

Mains cable connected to projector?

Check mains connection
and replace mains cable if necessary

Primary fuses defective

Replace fuses

(F1, F2, mains socket)

(see service instructions)

Projector voltage different from mains voltage

Check mains voltage setting on name plate.
If different from actual mains,
have service engineer make necessary change.
Important: Change name plate!
Inform ARRI-Service-Workshop

Rotating shutter not operating “E152”

Lamp cover not in position

Attach lamp cover, and clean

or safety switch not actuated.

actuation opening for safety switch

Temperature sensor in lamp housing

Switch on unit for cooling

has responded

(without switching on HTI lamp).
Allow 2 minutes for cooling off,
then briefly switch off and on
with mains switch. Ignite HTI lamp again.

T

rouble-Shooting

Advertising