60

Fault

Cause

Remedy

Film channel

Foreign matter in film channel.

Remove obstacle

“OPEN/CLOSE” function disturbed

Film loop cannot be formed

and actuate “Film” key once again.

Film not properly inserted

Tension film slightly on both film plates
with film channel open.
Film must drop totally to bottom of film channel.

Lamp cover not properly seated

Check film channel slide on lamp cover

or distorted

for easy running. If sluggish, replace
and lock lamp cover with film channel open.
If this fails, call Service Engineer.

Loop sensor dirty;

Clean with ARRI maintenance tools.

Reflex light barrier
on left loop box
doesn’t detect film loop.

Electronic board defective

Call ARRI Service station

Sudden stop during film transport

Film loop monitor switch has detected

Open and close film channel. Repeat film transport.

improper splicing or stapled film

In case of stapled film remove staples
and replace by splicing.
Then check pressure pad and film guiding elements
for possible damage.