Trouble-shooting – ARRI LOCPRO 35 User Manual

Page 65

Advertising
background image

65

Fault

Cause

Remedy

E-No. 132 >

Foreign matter at deflection runner 2.

Remove foreign matter.

Film channel opens again slightly
after closing, loop not completed.

E-No. 138 >

See E-No. 132.

See E-No. 132.

as E-No. 132, however, loop completed.

E-No. 142 >

Foreign matter in film channel.

Open film channel and remove foreign matter.

Main motor jamming during projection.

Check film track for possible damage.

Poor film splices.

Splice film properly and reinsert film.

Film sprocket roller jamming.

Take out film. Switch off mains switch.
Take off lamp cover and
carefully turn film sprocket roller by hand.
If it doesn’t turn,
call ARRI Service station.

Motor jamming.

Call ARRI Service station.

E-No. 144 >

See E-No. 142

See E-No. 142

Motor jamming during rewinding.

E-No. 146 >

See E-No. 142

See E-No. 142

See E-No. 142

T

rouble-Shooting

Advertising