Fault

Cause

Remedy

E-No. 108 >

See E-No. 102

See E-No. 102.

Carriage doesn’t close properly.

Shipping safety screw screwed in

Remove shipping safety screw.

E-No. 110 >

See E-No. 102

See E-No. 102.

Carriage doesn’t close or closes too slowly.

E-No. 112 >

See E-No. 102

See E-No. 102.

as E-No. 108 Dual loop almost completed.

E-No. 114 >

Film chips or splicing tape chips in film channel

Remove chips, clean film guide parts and remove

Dual loop cannot be completed.

or film emulsion deposits

emulsion deposits.

on film guide parts.

E-No. 120 >

See E-No. 102

See E-No. 102.

Film channel cannot be closed completely.

E-No. 122 >

See E-No. 114

See E-No. 114.

Last frame of dual loop
cannot be totally pulled in.

E-No. 124 >

Control error.

Repeat procedure several times.

Film channel opens again

If fault still exists after several attempts

slightly after closing.

(indicated by E-No. 124) call ARRI Service station.

T