Fault

Cause

Remedy

Sudden stop during film transport

Loop sensor and reflex protector

Clean with ARRI maintenance tools.

on left loop box dirty
with film dust.

Emulsion build-up in film channel.

Remove emulsion build-up from film pressure stage,
film track, deflection runner 1 and 2 and from film
pressure plate, using ARRI maintenance tools.

Operation too noisy

Improper length of film loop.

Open film channel and slightly tension film loop
manually by turning the two winding plates.
Then close film channel.
If fault still exists, call service engineer.

Film transport speed malfunctioning

Setting on master control knob

Call ARRI Service station.

doesn’t correspond to selected frame rate.

Autostop malfunctioning

Wrong film core.

Use correct film core diameter.

Film core diameter must correspond
to the one selected in
“Mode” function (Bobby Size).