4) Depress both locking brackets on plug

photo

and

pull off plug

photo

.

5) Unhinge both spring levers

photo

.

Attention: To avoid fingersprints HTI lamp
should only be touched with appropriate gloves.

6) Pull out defective HTI lamp upwards

7) Insert new HTI lamp (Id.No. M5.81802.0) so that it

snaps-in with its twist protector at the bottom right and
sits flat on the lamp carrier (within the four centering
pins).

8) Arrest on catch with both spring levers

photo

.

9) Hold one hand against the plug plate and plug in the

plug with the other hand until the catch snaps in.

10)Close plate hood, twist safety locking bar in locking

position and screw on. Attach lamp hood and arrest
snap locks.