Chapter 3:
Installation
The Harmonica must be installed in a suitable environment and properly connected to its
voltage supplies and the motor.
3.1. Before You Begin
3.1.1.
Site Requirements
You can guarantee the safe operation of the Harmonica by ensuring that it is installed in an
appropriate environment.
Feature
Value
Ambient operating temperature
0 °C to 40 °C (32 °F to 104 °F)
Maximum operating altitude
2,000 m (6562 feet)
Maximum relative humidity
90% non-condensing
Operating area atmosphere
No flammable gases or vapors permitted in area
Models for extended environmental conditions are available.
Caution:
The Harmonica drive dissipates heat by convection. The maximum operating
ambient temperature of 0 °C to 40 °C (32 °F to 104° F) must not be exceeded.
3.1.2.
Hardware Requirements
The components that you will need to install your Harmonica are:
Component
Connector Described
in Section
Drawing
Communication cable
(RS-232 or CAN)
J1
Page 33
1
Auxiliary feedback cable (if needed)
J2