I/o cables, A digital input (port j5) – ElmoMC SimplIQ Digital Servo Drives-Harmonica Installation Guide User Manual
Page 36
![background image](/manuals/558379/36/background.png)
Harmonica Installation Guide
Installation
MAN-HARIG (Ver. 1.902)
36
3.5.5.3.
I/O Cables
The following table lists the I/O cables that you should connect according to your specific
requirements:
Cable
Description
No.
Port
Digital
Digital input
6
J5
Digital
Digital output
2
J6
Analog
Analog input
1
J7
3.5.5.3.a
Digital Input (Port J5)
Notes for connecting the digital input cable:
•
Use 24 , 26 or 28 AWG twisted pair shielded cable. For best results, the shield should have
aluminum foil and copper braid.
•
Connect the cable shield to the ground near the signal source (controller).
Pin
(J5)
Signal Function
Pin Positions
1
IN1
Programmable input 1
(general purpose, RLS, FLS, INH)
2
IN2
Programmable input 2
(general purpose, RLS, FLS, INH)
3
IN3
Programmable input 3
(general purpose, RLS, FLS, INH)
4
IN4
Programmable input 4
(general purpose, RLS, FLS, INH)
5
IN5
Programmable input 5
(event capture, Main Home,
general purpose, RLS, FLS, INH)
6
IN6
Programmable input 6
(event capture, Auxiliary Home,
general purpose, RLS, FLS, INH)
7
INRET Programmable input return
8
INRET Programmable input return
Table 8: Digital Input Cable Pin Assignment