3.5.5.3.c
Analog Input (Port J7)
Notes for connecting the analog input cable:
•
Use 24, 26 or 28 AWG twisted pair shielded cable. For best results, the shield should have
aluminum foil and copper braid.
•
Connect the cable shield to the ground near the signal source (controller).
Pin (J7)
Signal
Function
Pin Positions
1
ANLIN1+
Analog input 1+
2
ANLIN1-
Analog input 1-
3
ANLRET
Analog ground
Table 10: Analog Input Cable Pin Assignments