Harmonica Installation Guide

Installation

MAN-HARIG (Ver. 1.902)

www.elmomc.com

26

Connect the main feedback cable from the motor to the J3 port on the front of the Harmonica,
using a 12-pin, Molex plug.

Notes for connecting the J3 cable:

Use 24 or 26 AWG twisted-pair shielded cables. For best results, the shield should have

aluminum foil covered by copper braid.

Connect the drain wire to pin 4.

The drain wire is a non-insulated wire that is in contact with parts of the cable, usually the
shield. It is used to terminate the shield and as a grounding connection.

Ground the shield to the motor chassis (except on resolver cables).

Figure 11: The Feedback (J3) Cable

Incremental
Encoder

Interpolated Analog
(Sine/Cosine)

Encoder

Resolver

Tachometer and
Potentiometer

HAR-

XX

/

YYY

_

HAR-

XX

/

YYY

I

HAR-

XX

/

YYY

R

HAR-

XX

/

YYY

T

Pin

(J3)

Signal Function

Signal Function

Signal Function

Signal Function

1

HC

Hall sensor C input HC

Hall sensor C input NC

-

HC

Hall sensor C input

2

HB

Hall sensor B input HB

Hall sensor B input NC

-

HB

Hall sensor B input

3

HA

Hall sensor A input HA

Hall sensor A input NC

-

HA

Hall sensor A input

4

SUPRET

Supply return

SUPRET

Supply return

SUPRET

Supply return

SUPRET

Supply return

5

SUPRET

Supply return

SUPRET

Supply return

SUPRET

Supply return

SUPRET

Supply return

6

+5V

Encoder/Hall
+5 V supply
voltage,
5 V @ 200 mA
maximum

+5V

Encoder/Hall
+5 V supply voltage,
5 V @ 200 mA
maximum

NC

-

+5V

Encoder/Hall
+5 V supply
voltage

Drain Wire