Installation

MAN-HARIG (Ver. 1.902)

www.elmomc.com

22

3.5.2.

Connecting the Power Cables (J8)

The main power connector, which is located on the bottom of the Harmonica, includes the
following pins:

Pin Function

Cable

Pin Positions

VP+ Power input, positive

Power

VP+ PR PE PE M1 M2 M3

PR Power input, common Power

PE Protective earth

Power

AC

Motor

Cable

DC

Motor

Cable

PE Protective earth

Motor Motor

M1 Motor phase

Motor N/C

M2 Motor phase

Motor Motor

M3 Motor phase

Motor Motor

Note:

When connecting several motors, all must

be wired in an identical manner.

Table 2: Connector for Main Power and Motor Cables

3.5.2.1.

Connecting the Motor Cable

Connect the motor power cable to the M1, M2, M3 and PE terminals of the main power
connector. The phase connection order is arbitrary because the Composer will establish the
proper commutation automatically during setup.

Notes for connecting the motor cables:

For best immunity, it is highly recommended to use a shielded (not twisted) cable for the

motor connection. A 4-wire shielded cable should be used. The gauge is determined by the
actual current consumption of the motor.

Connect the shield of the cable to the closest ground connection at the motor end.

The fourth wire should be used for the ground connection between the motor and the

second PE terminal of the Harmonica.

Be sure that the motor chassis is properly grounded.

PR

VP+

PE

PE

M1

M2

M3