Environmental conditions – ElmoMC SimplIQ Digital Servo Drives-Harmonica Installation Guide User Manual

Page 51

Advertising
background image

Harmonica Installation Guide

Technical Specifications

MAN-HARIG (Ver. 1.902)

www.elmomc.com

51

4.4. Environmental Conditions

Feature

Details

Operating ambient temperature

according to IEC60068-2-2

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing humidity

according to IEC60068-2-78

95%

Maximum Operating Altitude

2,000 m (6562 feet)

Mechanical Shock

according to IEC60068-2-27

15g / 11ms Half Sine

Vibration

according to IEC60068-2-6

5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G

Advertising