4.9.2.

Digital Output Interface

Feature

Details

Connector Location

Type of output

Optically isolated

Open collector and open emitter

Maximum supply
output (Vcc)

30 V

Maximum output
current
Io (max) (Vout =
Low)

Iout (max) ≤ 10 mA

VOL @ maximum
output voltage (low
level)

Vout (on) ≤ 0.3 V + 0.02 * Iout (10 mA)

RL

External resistor RL must be selected to limit
output current to no more than 10 mA.

(max)

Io

VOL

Vcc

R

L

=

Executable time

If output is set to one of the built-in
functions — Home flag, Brake or AOK —
execution is immediate upon detection:
0 < T < 4 x TS
If output is set to General output and is
executed from a program, the typical time is
approximately 0.5 msec.

Rout = 20

33v

OUTput Ret(i)

OUTput (i)

Figure 33: Digital Output Schematic