AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Operation in advanced display mod

Pressing the OK button continues with the actual test, ESC/SERVICE cancels the
process.

Now the new slave can be connected to the AS-i network. After connecting, the
current address of the slave is displayed as "OLD ADDRESS"and the message
"CONNECT NEW SLV" disappears.

To assign a new address to the slave the menu entry "NEW ADDRESS" must be
selected. Afterwards the new address can be selected by using the arrow but-
tons. The selected address is assigned by selecting "PRG" on the menu and
pressing the OK button.

If an error occurs while addressing a slave, one of the following error messages is
displayed for about 2 seconds:

SLAVE ADR TOOL
CONNECT NEW SLV
OLD ADDRESS
NEW ADDRESS

SLAVE ADR TOOL
CONNECT
OLD ADDRESS 21A
NEW ADDRESS 03B
PRG

Failed: SND: Slave with old address has not been detected.

Failed: SD0: Slave with address 0 already exists.

Failed: SD2: Chosen slave address already exists.

Failed: DE: AS-i slave address cannot be deleted.

Failed: SE: Error setting new address for AS-i slave.

Failed: AT: New address for AS-i slave could be stored temporarily only.

Failed: RE: Error reading extended ID1-code.

Information!

When working with a double master (AS-i master and two AS-i networks) the AS-i net-
work must be selected first by using the arrow and the OK buttons.

AS-I CIRCUIT 1
AS-i CIRCUIT 2