4 ext safety mon (external monitor), Monitor config, Ext safety mon (external monitor) – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual

Page 92

Advertising
background image

92

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Operation in advanced display mod

9.6.3.3

MONITOR CONFIG

Main Menu|| DIAGNOSIS || MONITOR || VIEW CONFIG || MONITOR CONFIG ||

This menu indicates which configuration is loaded in the integrated Safety Moni-
tor.

9.6.4

EXT SAFETY MON (external monitor)

Main menu || DIAGNOSIS || EXT MONITOR || EXT SAFETY MON ||

The AS-i Safety Monitor diagnostics reads the diagnostics data from the AS-i
Safety Monitor and shows this diagnostics data in the display.

The menu item ADDRESS can be used to select the desired external monitor.

For additional information, please refer to the <ASIMON> documentation.

Generation 2 external monitors always have unsorted diagnostics.

SAFETY MONITOR
DIAGNOSIS
LAST DIAGNOSIS
VIEW CONFIG

MONITOR CONFIG
COMPLETE
CONFIGURATION
FGDG
MON.VER.: 3.0
RELEASED
BY SA
ON 2007/11/15
AT: 14:30
RELEASED CODE:
81FE

EXT SAFETY MON
DIAGNOSIS
ADDRESS 10
MODE: SORTED/V1
OK