58

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Function and startup of the Safety Monitor

8.6

Safe coupling slaves on the AS-i circuits

The two AS-i circuits are capable of emulating a total of up to sixteen safe cou-
pling slaves which indicate the states of the two safe relay outputs.

The addresses of the coupling slaves can be set from the display or using the
AS-i Control Tools.

The code sequences of the coupling slaves are stored in the AS-i Master at man-
ufacture and are individual for each device. If an AS-i Safety Monitor needs to be
replaced, the monitors which have incorporated the coupling slaves of an AS-i
Safety Monitor in their configuration need to be re-taught (e.g. through the menu
or using the ESC/Service key).

8.7

Chip card

The chip card is divided into two areas. One area is reserved for unsafe data and
administration, the other for safe data.

8.7.1

Unsafe data

This section describes the system behavior of the unsafe system section when
using the chip card.

8.7.1.1

Card unformatted

If an unformatted card is found when the device is started, the following is dis-
played:

The chip card is formatted and then the data copied to the chip card.

Warning!

Always turn off power before inserting or removing the card.

NEW CHIPCARD
WILL BE FORMATED
AS-I DATA WILL
BE SYNCHRONIZED

Advertising