Data not compatible, Card empty, Data compatible – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual

Page 59: Data in the device and on the chip card identical

Advertising
background image

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Function and startup of the Safety Monitor

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

59

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

8.7.1.2

Data not compatible

If a card is found whose data are incompatible with the device, the following error
message is displayed:

8.7.1.3

Card empty

The following message is displayed for an empty card:

From this time on all changes are made both in the device and on the chip card.

8.7.1.4

Data compatible

If when starting with an empty device (e.g. after a factory reset) a non-empty card
is found whose data are compatible with the device, the following message is dis-
played:

The card configuration is written to the device. From this time on all changes are
made both in the device and on the chip card.

8.7.1.5

Data in the device and on the chip card identical

If the card and device are not empty at start and the data are identical, no mes-
sage is displayed.

8.7.1.6

Data in the device and on the chip card not identical

If the card and device are not empty at start and the data are not identical, an er-
ror message is displayed and the card is not synchronized with the device. The
following menu is then automatically opened:

NEW CHIPCARD
WILL BE FORMATED
AS-I DATA WILL
BE SYNCHRONIZED

CHIPCARD FOUND
AS-I DATA WILL
BE SYNCHRONIZED

AS-I DATA FROM
CHIPCARD TAKEN