Function and startup of the Safety Monitor

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

61

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

8.7.1.9

Data compatible

If a card with an empty active memory bank is found, the safety configuration in-
cluding code sequences is written to the card and in future all changes are made
in the card and in the device at the same time. The following message is dis-
played on the device:

8.7.1.10

Complete configuration

If when starting with an empty device a card with a released safety configuration
including code sequences is found (Complete safety configuration) in the active
memory bank, this configuration is written to the device, then the menu for releas-
ing using Release Code is opened:

If the active bank contains a Complete Configuration and if the data in the active
bank on the memory card and the data in the device are identical (e.g. both emp-
ty), in future all changes are made in the card and in the device at the same time.

8.7.1.11

Data on the chip card and in the device are identical

If the card and device are not empty at start and the data are identical, no mes-
sage is displayed.

CHIPCARD FOUND.
SAFETY DATA WILL
BE SYNCHRONIZED

COPY BANK A
TO MONITOR
RELEASE DATE:
2006/06/17 18:43
BY: ROLF BECKER
CONFIG NAME:
L3040 MIT LADEVO
RRICHTUNG LINKU
ND PALETTENWECHS
LER V1.23
RELEASE CODE: 1BDF
- - - - - - - - -

- - - - - -

TYPE CODE
1BDF

OK