2 function of the esc/service key, Function of the esc/service key – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual

Page 57

Advertising
background image

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Function and startup of the Safety Monitor

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

57

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

After entering the PIN, the display can be used to start a teaching procedure
for the code sequences. The monitor stops immediately after entering the
PIN. After teaching, the monitor starts after a prompt and acknowledgement
on the display.

Legend: "

3

" = possible; "–" = not possible

Code sequences for releasing a configuration do not necessarily have to have
been successfully learned. It is also possible to release without code sequences,
which must then be learned at a later time. An AS-i Gateway with integrated AS-i
Safety Monitor does not go into the protecting operating mode without learned
code sequences.

Teaching the code sequences is simple to perform:

Using the ESC/Service key (See section <Replacing a defective safety-con-
figured AS-i slave>)

or

Using the display (See section <TEACH CODES>).

8.5.2

Function of the ESC/Service key

In traditional (classical) display mode, the ESC/Service key takes on two kinds of
functions:

Briefly pressing the ESC/Service key unlocks the Safety Monitor when red is
flashing

A longer press (3s) starts the teach procedure for a slave.

Action

ASIMON Software

On AS-i Safety Monitor

Configure and load into Safety
Monitor

3

3

(only from chip card)

Stopping

3

3

Releasing

3

Starting

3

3

Teaching code sequences

3

3

Changing the password

3

3

(only from chip card)

Changing the PIN

3

Information!

For additional information see section <Replacing a defective safety-configured AS-i
slave>.