AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Spezifications

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

23

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

103374

4 x LED output circuit

state of output circuit
LED off:

open

LED on:

closed

Electrical data

Operating current

master power supply, approx. 300 mA out of the AS-i network 1,
approx 70 mA out of the AS-i network 2

Operating voltage

AS-i voltage 30 V

DC

24 V

DC

for the outputs K3, K4

Voltage of insulation

t 500 V

Standards

EN 61 000-6-2, EN 61 000-6-4
EN 62 061, SIL3
EN 61 508, SIL3
EN 13 849, performance level e

Housing

AS-i master housing in stainless steel

Ambient operating temperature

0°C … +55°C

Storage temperature

-25°C … +85°C

Dimensions (L / W / H in mm)

120 / 100 / 96

Protection category IEC 60 529

IP20

Tolerable loading referring to impacts
and vibrations

according to EN 61 131-2

Weight

800 g

Safety Monitor block diagram:

Connections:

Sicherheitsmonitor
(Safety Monitor)

1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)

1.13

1.14

2.13

2.14

Eingänge
(Inputs)

Freigabe
(Release)

0 V

4.14

24 V

3.14

Freigabe
(Release)

Freigabe
(Release)

Freigabe
(Release)

Freigabe
(Release)

Freigabe
(Release)

Freigabe
(Release)

Freigabe
(Release)

+

-

+

-

+

-

+

PROFIBUS

2.13

+

24 V

2.Y1

0 V

+

1.13

2.Y2

1.Y2

2.14

+

4.14

+

1.14

1.Y1

3.14

+ ASI 2

+ASI 1–

+

-

ASI 1 +PWR- (max. 8A)

ASI 2 +PWR- (max. 8A)

Gateway + Safety Monitor

output switching elements

EDM/START inputs

EDM/START inputs

output switching elements