2 parameter setting – Lenze E94AYFLF Digital frequency module User Manual

Page 10

Advertising
background image

Digital frequency extension module | Parameter setting & configuration

Digital frequency input

Parameter setting

10

L

EDS94AYFLF EN 3.2 - 10/2010

2.2

Parameter setting

Short overview of the parameters for the digital frequency input:

Note!

Depending on the module receptacle the digital frequency extension module is

plugged in, different code ranges are assigned to the parameters!
• Module receptacle MXI1: Parameters are in the C130xx range
• Module receptacle MXI2: Parameters are in the C140xx range

Parameter

Info

Lenze setting

Value Unit

C13010

C14010

Encoder type DFIN

Digital frequency output DFOUT

C13011

C14011

No. of increments DFIN

2048

C13012

C14012

Signal form DFIN

4x evaluation (A, B)

C13013

C14013

Initialisation time DFIN

3000 ms

C13014

C14014

Track monitoring DFIN

Active after initialisation time

C13021

C14021

TP delay time DFIN

0 μs

C13030

C14030

Speed at DFIN

- Incr./ms

C13031

C14031

Frequency at DFIN

- Hz

C13032

C14032

Position at DFIN

- Increments

C13040

C14040

Resp. to track monitoring DFIN

Warning

C13041

C14041

No resp. to DFIN enable signal

Warning

C13042

C14042

Resp. to Vcc error DFIN

Warning

 Digital frequency extension module in module receptacle MXI1

 Digital frequency extension module in module receptacle MXI2

Greyed out = display parameter