Digital frequency extension module | Parameter setting & configuration

Digital frequency output

System block "LS_DigitalFrequencyOutput"

3.4

System block "LS_DigitalFrequencyOutput"

The system block LS_DigitalFrequencyOutput displays the digital frequency output of the

optional extension module in the FB editor of the »Engineer«:

Inputs

Input

Data type

Info/possible settings

DFOUT_dnSpeedSet_s

DINT

Speed in [rpm], which is to be output via the digital frequency output as encoder

signals with TTL level.

• To select this signal source,

C13050

/

C14050

= "7" must be set.



Signal source selection ( 23)

DFOUT_bLoadReferencePos

BOOL

Position setting



Position setting ( 25)

FALSEÊTRUE Sets the 32-bit absolute position output at the output

DFOUT_dnActualPos_p to the value which is applied to input

DFOUT_dnReferencePos_p.

DFOUT_dnReferencePos_p

DINT

Absolute position in [increments], to which the output DFOUT_dnActualPos_p is set

by a FALSE-TRUE edge at input DFOUT_bLoadReferencePos.



Position setting ( 25)

DFOUT_AxisData

V3.0 or higher

Machine parameters

• To transfer the machine parameters of the drive/motor, connect this input to the

output DI_AxisData of SB LS_DriveInterface.

• The machine parameters of a higher-level drive can be transferred via the

FB L_SdSetAxisData. For this purpose, you have to connect the FB's AxisData

output to this input.

• If the input remains unused, the system block continues to operate as before. In

this case the units are scaled to revolutions.



Use of machine parameters for scaling ( 26)

/6B'LJLWDO)UHTXHQF\2XWSXW

')287BGQ5HIHUHQFH3RVBS

'

BE/RDG5HIHUHQFH3RV

)287

'

BGQ$FWXDO3RVBS

)287

'

BGQ$FWXDO6SHHGBV

)287

'

BE2XWSXW)UHT/LPLWHG

)287

;

')287BGQ6SHHG6HWBV

')287B$[LV'DWD