Digital frequency extension module | Parameter setting & configuration

Parameter reference

Parameter list | C13075

38

L

EDS94AYFLF EN 3.2 - 10/2010

C13075

C13076

C13077

C13080

Parameter | Name:

C13075 | Unit

Data type: VISIBLE_STRING

Index: 11500

d

= 2CEC

h

Subcodes

Info

C13075/1

Unit for the position

C13075/2

Unit for the speed

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C13076 | Actual position DFOUT

Data type: INTEGER_32

Index: 11499

d

= 2CEB

h

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Scaling factor: 10000

Parameter | Name:

C13077 | Actual speed DFOUT

Data type: INTEGER_32

Index: 11498

d

= 2CEA

h

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Scaling factor: 10000

Parameter | Name:

C13080 | Resp. to freq. limit. DFOUT

Data type: UNSIGNED_8

Index: 11495

d

= 2CE7

h

Digital frequency extension module in module receptacle MXI1:

Response when limit frequency for digital frequency output X10 is reached.

• Is executed if the digital frequency reaches the limit value set in

C13053

.

Selection list

(Lenze setting in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response

;

Read access ; Write access … CINH … PLC-STOP … No transfer