2 number of increments and zero pulse offset – Lenze E94AYFLF Digital frequency module User Manual

Page 24

Advertising
background image

Digital frequency extension module | Parameter setting & configuration

Digital frequency output

Parameter setting

24

L

EDS94AYFLF EN 3.2 - 10/2010

3.2.2

Number of increments and zero pulse offset

The number of increments set in

C13051

/

C14051

defines e.g. the number of increment to

be output before a zero pulse is created.

 Each zero pulse defines a covered "revolution" of the rotary transducer simulated by the

digital frequency output.

 Within such a "revolution" (in the value range 0 ... 65535 increments) the zero pulse can

be shifted by setting a zero pulse offset in

C13052

/

C14052

.

A connection between absolute position and "revolution" is defined by setting the position,

as described in the following chapter "

Position setting

". The position of a zero pulse within

a "revolution" remains unchanged.

Example - signal characteristic:

[3-2]

Example: Signal characteristic with the zero pulse offset set to 39321 increments

6

Output of the encoder angle

• The angle of rotation in [increments] derived from the encoder input is output as a frequency

signal after being evaluated with the set number of increments (

C13051

/

C14051

).

• The output signal is integrated to a position value via a counter and made available to the

application via the output DFOUT_dnActualPos_p of the system block

LS_DigitalFrequencyOutput.

• It is irrelevant for the output whether the encoder input is used as a load encoder, motor encoder,

or not used at all for the motor control.

7

Output of a speed signal of the application

• The speed signal in [rpm] defined via the input DFOUT_dnSpeedSet_s of the system block

LS_DigitalFrequencyOutput is integrated and output as a frequency signal after being evaluated

with the set number of increments (

C13051

/

C14051

).

• The output signal is integrated to a position value via a counter and made available to the

application via the output DFOUT_dnActualPos_p of the system block

LS_DigitalFrequencyOutput.

Selection

Info

n

Absolute position (DFOUT_dnActualPos_p, also takes into account each overflow of the encoder position)

o

Position difference (is determined by

Position setting

)

p

Encoder position (in the value range 0 ... 65535 increments)

q

Zero pulse offset (adjustable in

C13052

/

C14052

)

r

Zero pulses

39321

65535

t

t

Œ



[Inc]



0

Ž



DFOUT_dnActualPos_p

Advertising