C14075 | unit, C14076 | actual position dfout, C14077 | actual speed dfout – Lenze E94AYFLF Digital frequency module User Manual

Page 44: C14080 | resp. to freq. limit. dfout, C14080, C14075/1, C14075/2, C14076, C14077

Advertising
background image

Digital frequency extension module | Parameter setting & configuration

Parameter reference

Parameter list | C14075

44

L

EDS94AYFLF EN 3.2 - 10/2010

C14075

C14076

C14077

C14080

Parameter | Name:

C14075 | Unit

Data type: VISIBLE_STRING

Index: 10500

d

= 2904

h

Subcodes

Info

C14075/1

Unit for the position

C14075/2

Unit for the speed

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14076 | Actual position DFOUT

Data type: INTEGER_32

Index: 10499

d

= 2903

h

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Scaling factor: 10000

Parameter | Name:

C14077 | Actual speed DFOUT

Data type: INTEGER_32

Index: 10498

d

= 2902

h

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Scaling factor: 10000

Parameter | Name:

C14080 | Resp. to freq. limit. DFOUT

Data type: UNSIGNED_8

Index: 10495

d

= 28FF

h

Digital frequency extension module in module receptacle MXI2:

Response when limit frequency for digital frequency output X10 is reached.

• Is executed if the digital frequency reaches the limit value set in

C14053

.

Selection list

(Lenze setting in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response

;

Read access ; Write access … CINH … PLC-STOP … No transfer