C14015 | encoder mounting dir. (dfin), C14021 | tp delay time dfin, C14030 | speed at dfin – Lenze E94AYFLF Digital frequency module User Manual

Page 40: C14031 | frequency at dfin, C14032 | position at dfin, C14035 | unit, C14021, C14030, C14031, C14032

Advertising
background image

Digital frequency extension module | Parameter setting & configuration

Parameter reference

Parameter list | C14015

40

L

EDS94AYFLF EN 3.2 - 10/2010

C14015

C14021

C14030

C14031

C14032

C14035

Parameter | Name:

C14015 | Encoder mounting dir. (DFIN)

Data type: UNSIGNED_32

Index: 10560

d

= 2940

h

Selection list

(Lenze setting in bold)

Info

0 Clockwise direction of rotation
1 Counter-clockwise direction of

rotation

;

Read access ; Write access ; CINH … PLC-STOP … No transfer

Parameter | Name:

C14021 | TP delay time DFIN

Data type: UNSIGNED_32

Index: 10554

d

= 293A

h

Digital frequency extension module in module receptacle MXI2:

Touch probe delay for digital frequency input X9

• The delay time set is considered when the position at the instant of touch probe is determined (instant of zero

pulse) and serves to compensate dead times, if existent.

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

7000 0 μs

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14030 | Speed at DFIN

Data type: INTEGER_32

Index: 10545

d

= 2931

h

Digital frequency extension module in module receptacle MXI2:

Display of the current speed at digital frequency input X9
Display range

(min. value | unit | max. value)

-2147483648

Incr./ms

2147483647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14031 | Frequency at DFIN

Data type: INTEGER_32

Index: 10544

d

= 2930

h

Digital frequency extension module in module receptacle MXI2:

Display of the current frequency at digital frequency input X9
Display range

(min. value | unit | max. value)

-2147483648

Hz

2147483647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14032 | Position at DFIN

Data type: INTEGER_32

Index: 10543

d

= 292F

h

Digital frequency extension module in module receptacle MXI2:

Display of the current position at digital frequency input X9
Display range

(min. value | unit | max. value)

-2147483648

Incr.

2147483647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14035 | Unit

Data type: VISIBLE_STRING

Index: 10540

d

= 292C

h

Subcodes

Info

C14035/1

Unit for the position

C14035/2

Unit for the speed

;

Read access … Write access … CINH … PLC-STOP … No transfer