C14053 | frequency limitation dfout, C14061 | tp delay time dfout, C14070 | speed at dfout – Lenze E94AYFLF Digital frequency module User Manual

Page 43: C14071 | frequency at dfout, C14072 | position at dfout, C14053, C14061, C14070, C14071, C14072

Advertising
background image

EDS94AYFLF EN 3.2 - 10/2010

L

43

Digital frequency extension module | Parameter setting & configuration

Parameter reference

Parameter list | C14053

C14053

C14061

C14070

C14071

C14072

Parameter | Name:

C14053 | Frequency limitation DFOUT

Data type: UNSIGNED_16

Index: 10522

d

= 291A

h

Digital frequency extension module in module receptacle MXI2:

Limit frequency for digital frequency output X10

• Frequency to which the digital frequency output is limited by the software.

• If the limit value is reached, the response set in

C14080

is executed.

• In terms of the hardware, the digital frequency output is limited to 500 kHz.

• If the digital frequency input is directly connected to the digital frequency output, the set frequency limitation

is functionless!

Note: Du to the remainder processing implemented in the 4 kHz control cycle, only settings ≥ 4 kHz are reasonable

for frequency limitation!


Frequency limitation

Setting range

(min. value | unit | max. value)

Lenze setting

1

kHz

500 500 kHz

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14061 | TP delay time DFOUT

Data type: UNSIGNED_32

Index: 10514

d

= 2912

h

Digital frequency extension module in module receptacle MXI2:

Touch probe delay for digital frequency output X10

• The delay time set is considered when the position at the instant of touch probe is determined (instant of zero

pulse) and serves to compensate dead times, if existent.

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

7000 0 μs

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14070 | Speed at DFOUT

Data type: INTEGER_32

Index: 10505

d

= 2909

h

Digital frequency extension module in module receptacle MXI2:

Display of the current speed at digital frequency output X10
Display range

(min. value | unit | max. value)

-2147483648

Incr./ms

2147483647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14071 | Frequency at DFOUT

Data type: INTEGER_32

Index: 10504

d

= 2908

h

Digital frequency extension module in module receptacle MXI2:

Display of the current frequency at digital frequency output X10
Display range

(min. value | unit | max. value)

-2147483648

Hz

2147483647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14072 | Position at DFOUT

Data type: INTEGER_32

Index: 10503

d

= 2907

h

Digital frequency extension module in module receptacle MXI2:

Display of the current position at digital frequency output X10
Display range

(min. value | unit | max. value)

-2147483648

Incr.

2147483647

;

Read access … Write access … CINH … PLC-STOP … No transfer