7 touch probe – Lenze E94AYFLF Digital frequency module User Manual

Page 16

Advertising
background image

Digital frequency extension module | Parameter setting & configuration

Digital frequency input

Parameter setting

16

L

EDS94AYFLF EN 3.2 - 10/2010

2.2.7

Touch probe

When the zero pulse occurs on track Z - Z, a touch probe is triggered.

 The corresponding signals to execute touch probe processing are available via the

system block LS_TouchProbeDFIN.

 In

C13021

/

C14021

a delay time can be set for the touch probe.

 If a touch probe has been triggered, the output DFIN_bTouchProbeReceived is set to

TRUE for one cycle.

Tip!
Detailed information on touch probe processing can be found in the online

documentation for the controller in chapter "I/O terminalsTouch probe

detection".

Advertising