C14036 | actual position dfin, C14037 | actual speed dfin, C14040 | resp. to track monitoring dfin – Lenze E94AYFLF Digital frequency module User Manual

Page 41: C14041 | resp. to dfin enable sig. miss, C14040, C14041, C14036, C14037, Is executed

Advertising
background image

EDS94AYFLF EN 3.2 - 10/2010

L

41

Digital frequency extension module | Parameter setting & configuration

Parameter reference

Parameter list | C14036

C14036

C14037

C14040

C14041

Parameter | Name:

C14036 | Actual position DFIN

Data type: INTEGER_32

Index: 10539

d

= 292B

h

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Scaling factor: 10000

Parameter | Name:

C14037 | Actual speed DFIN

Data type: INTEGER_32

Index: 10538

d

= 292A

h

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

;

Read access … Write access … CINH … PLC-STOP … No transfer

Scaling factor: 10000

Parameter | Name:

C14040 | Resp. to track monitoring DFIN

Data type: UNSIGNED_8

Index: 10535

d

= 2927

h

Digital frequency extension module in module receptacle MXI2:

Response when track monitoring is triggered for digital frequency input X9

• Track monitoring is triggered if a signal cable (A, B, or Z) is interrupted.
Selection list

(Lenze setting in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C14041 | Resp. to DFIN enable sig. miss.

Data type: UNSIGNED_8

Index: 10534

d

= 2926

h

Digital frequency extension module in module receptacle MXI2:

Response when "Enable" signal at digital frequency input X9 fails
Selection list

(Lenze setting in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Advertising