C13010 | encoder type dfin, C13011 | no. of increments dfin, C13012 | signal format dfin – Lenze E94AYFLF Digital frequency module User Manual

Page 33: C13013 | initialisation time dfin, C13014 | track monitoring dfin, C13010, C13011, C13012, C13013, C13014

Advertising
background image

EDS94AYFLF EN 3.2 - 10/2010

L

33

Digital frequency extension module | Parameter setting & configuration

Parameter reference

Parameter list | C13010

C13010

C13011

C13012

C13013

C13014

Parameter | Name:

C13010 | Encoder type DFIN

Data type: UNSIGNED_8

Index: 11565

d

= 2D2D

h

Digital frequency extension module in module receptacle MXI1:

Selection of the encoder type for digital frequency input X9
Selection list

(Lenze setting in bold)

1 Digital frequency output DFOUT
2 TTL encoder

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C13011 | No. of increments DFIN

Data type: UNSIGNED_32

Index: 11564

d

= 2D2C

h

Digital frequency extension module in module receptacle MXI1:

Number of increments for digital frequency input X9

• Definition of the number of pulses for one "mechanical" revolution.
Setting range

(min. value | unit | max. value)

Lenze setting

1

16384 2048

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C13012 | Signal format DFIN

Data type: UNSIGNED_8

Index: 11563

d

= 2D2B

h

Digital frequency extension module in module receptacle MXI1:

Signal form for digital frequency input X9

• Selection of how to interpret the input signal.
Selection list

(Lenze setting in bold)

0 4x evaluation (A, B)
1 A:Increments B:Sign
2 Increments A:pos. B:neg.

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C13013 | Initialisation time DFIN

Data type: UNSIGNED_16

Index: 11562

d

= 2D2A

h

Digital frequency extension module in module receptacle MXI1:

Initialisation time for digital frequency input X9

• Waiting time after which the "Enable" signal is evaluated and the track monitoring modes are switched active.
Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 3000 ms

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C13014 | Track monitoring DFIN

Data type: UNSIGNED_8

Index: 11561

d

= 2D29

h

Digital frequency extension module in module receptacle MXI1:

Monitoring configuration for digital frequency input X9

• Selection when track monitoring modes (open circuit detection) are active.
Selection list

(Lenze setting in bold)

1 Active after initialisation time
2 Active after enable signal

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Advertising