L

EDS94AYFLF EN 3.2 - 10/2010

2.2.5

Voltage control - TTL encoder

If a TTL encoder is connected as the signal source and

C13010

/

C14010

is set to TTL

encoder, the encoder can be supplied with a controlled +5 V voltage via pin 4, which serves

to compensate the voltage drop on the encoder cable.

2.2.6

Monitoring

Initialisation time
In

C13013

/

C14013

an initialisation time can be set, which must elapse after starting the

system before the monitoring modes are switched active.

 Thanks to this "delay" other system parts which serve as signal sources, can initialise

themselves first without monitoring being triggered due to missing signals.

 In the "0" setting the initialisation time is set to infinity so that monitoring is

deactivated permanently.

 If the setting is changed from "0" to another value, the initialisation time is restarted.

– A higher-level control can, for instance, switch monitoring active by a corresponding

parameter setting of

C13013

/

C14013

even if the device has been switched on for a

long time.

Monitoring of the +5 V voltage for the encoder
If an encoder is connected to X9 and supplied by the digital frequency extension module

"in a controlled way", the pin 8 of the digital frequency input X9 serves to control and

monitor the +5 V encoder voltage.

 If the voltage control is not able to compensate the voltage drop, a fault message is

created and the response set in

C13042

/

C14042

is executed.

– At the same time the output DFIN_bVccCtrlLimited of the system block

LS_DigitalFrequencyInput is set to TRUE.

Stop!

If an encoder is connected to X9 and supplied by the digital frequency extension

module "in a controlled way", the pin 8 of the digital frequency input X9 serves

to control and monitor the +5 V encoder voltage.



Monitoring

In this case, no digital signal ("Lamp control" or "Enable") may be supplied to PIN

8!
Please also observe the documentation for the encoder used.