In order that the input signals are interpreted correctly from the digital frequency

extension module, the setting in

C13012

/

C14012

must correspond to the signal form of

the input signals applied:

4x evaluation (A, B)

A:Increments B:Sign

Increments A:pos. B:neg.

Setting C13012 / C14012 = "0"

Phase-displaced signal sequence (CW

rotation)

CW rotation

CCW rotation

Track A leads track B by 90°

lags track B by 90°

Track B -

-

Setting C13012 / C14012 = "1"

Control of the direction of rotation via track B

CW rotation

CCW rotation

Track A transmits the speed

transmits the speed

Track B = FALSE

= TRUE

Setting C13012 / C14012 = "2"

Control of speed and direction of rotation via

track A or track B

CW rotation

CCW rotation

Track A transmits speed and

direction of rotation

= FALSE

Track B = FALSE

transmits speed and

direction of rotation