Dfin (mxi2): track error a-/a [0x00aa0000, Dfin (mxi2): track error b-/b [0x00aa0001, Dfin (mxi2): track error z-/z [0x00aa0002 – Lenze E94AYFLF Digital frequency module User Manual

Page 50: Fault messages

Advertising
background image

Digital frequency extension module | Parameter setting & configuration

Fault messages

50

L

EDS94AYFLF EN 3.2 - 10/2010

DFIN (MXI2): Track error A-/A [0x00aa0000]

DFIN (MXI2): Track error B-/B [0x00aa0001]

DFIN (MXI2): Track error Z-/Z [0x00aa0002]

DFIN (MXI2): Signal error enable/lamp control [0x00aa0003]

DFIN (MXI2): Supply cannot be corrected anymore [0x00aa0004]

DFOUT (MXI2): Maximum frequency reached [0x00aa0005]

Response (Lenze setting in bold)

Setting:

C14040

(; Adjustable response)

;

No … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of signal cable for track A.

• Check signal cable for track A.

• Check encoder.

Response (Lenze setting in bold)

Setting:

C14040

(; Adjustable response)

;

No … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of signal cable for track B.

• Check signal cable for track B.

• Check encoder.

Response (Lenze setting in bold)

Setting:

C14040

(; Adjustable response)

;

No … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of signal cable for track Z.

• Check signal cable for track Z.

• Check encoder.

Response (Lenze setting in bold)

Setting:

C14041

(; Adjustable response)

;

No … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of signal cable for "Enable"

signal or no "Enable" signal available.

• Check signal cable for "Enable" signal.

• Check encoder.

Response (Lenze setting in bold)

Setting:

C14042

(; Adjustable response)

;

No … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI2: The

encoder voltage controlled by the digital frequency input

has reached the voltage limit.

Check encoder.

Response (Lenze setting in bold)

Setting:

C14080

(; Adjustable response)

;

No … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information

Cause

Remedy

Digital frequency extension module in MXI2: Limit

frequency at the digital frequency output reached.

• The digital frequency has reached the limit value set

in

C014053

.

Check set limit value.

Advertising