1. Metal Roof Deck Panels* - No. 24 MSG steel or stainless steel or 0.030 in. thick aluminum, nom 18 in. wide,

2-3/8 in. high standing seams. Heavier gauges or narrower panels acceptable. Panels continuous over two or

more spans. Floating end laps to occur over purlins with panels overlapped 8 in. End lap to begin 3 in. from purlin

web and to extend across purlin flange. A bead of mastic sealant may be used at panel end and side laps.

2. Panel Clips* - No. 16 MSG min gauge coated steel or stainless steel, 6 in. long by 2.718 in. high. Base to have

four .281 in. dia. guide holes to accommodate screw fasteners (Item 4). Clips spaced 48" on center maximum,

fastened throught metal decking.

3. Cap - Used at seam, nom 1 in. wide, 1/2 in. deep fabricated from min No. 24 MSG steel, stainless steel or 0.030

in. thick aluminum. Cap continuously seamed over panel seams with a special motorized seaming tool. Seaming

process to include panel clips (Item 2)

4. Fasteners - (Screws) - Fasteners used to attach panel clips (Item 2) to liner panel to be No. 12 self-tapping, hex-

head, plated or stainless steel screw without washers or #14-13 with No. 3 phillips head Deck Screw. Two fasten-

ers per clip to be used. Fasteners used to attach thermal spacer (Item 9) to purlins to be same type spaced 18 in.

OC. Fasteners used at end lap to be expanding bolt type with an aluminum sleeve having a 5/8 in. diam cap with a

1/4-20 by 1-7/16 in. long stainless steel bolt. Spacing at end lap to be 1, 3, 3, 4, 3, 3 in. pattern. Length to depend

on thickness of insulation and/or thermal spacers and to be 3/4 in. longer than overall depth of deck assembly.

5. Foamed Plastic - (Optional) - Extruded foamed plastic (rigid Insulation) min density 2.00 pcf supplied in min thick-

ness 1 in., max thickness 4 in.

6. Liner Panel - Fabricated from No. 22 MSG min thickness coated steel. Min depth 15/16 in., max pitch 7.2 in., min

yield strength 33 ksi. or 18/20 MSG thickness (No 22 MSG min) coated steel, 4-1/2 in. deep, (24 in. coverage), min

yield strength 33 ksi. Max span of panel units to be per manufacturer's instructions. Panels attached to structural

supports with screws or welds per liner panel manufacturer's instructions.

7. Bearing Plate - (Optional) - No. 22 MSG steel, 6 in. by 6 in. Used with rigid insulation only.

8. Supports (Purlins) - (Not Shown) - Purlins used for liner panels to be cold fomred steel sections. As alternates,

structural steel components (hot rolled beams, channels, open web joist etc.) may be used. Min gauge and yield

to depend on design considerations. Max spacing to depend on design considerations.

9. Thermal Spacer - (Optional) - (Not Shown) - Located over liner panel at panel clip locations. Continuous nom

wood 2 in. by 4 in. Not used when foamed plastic (Item 5) is used.

Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evalu-

ated.

10. Plywood or OSB - (Optional) (Not Shown) - Min APA rated plywood, nom 1/2 in. thick or oriented strand board

(OSB), nom 7/16 in. thick, 4 x 8 ft. Sheets to be installed on top of Foamed Plastic (Item 5) in lieu of bearing plates

(Item 7)

*Bearing the UL Classification Mark

Construction No. 268A

July 15, 2013

Uplift - Class 90

Fire Not Investigated