Step 4, Caution, Installation of panel – Metal Sales T-Armor Series User Manual

Page 50

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 09/14

50

INSTALLATION OF PANEL (

cont

.)

INSTALLING PANEL CLIPS

Note: The following procedures are based on installing panel clips over steel purlins. For fastening

clips to a substructure other than steel, (see page 44). Design wind uplift requirements and insulation

thickness must be considered for proper selection of clip type, size, and spacing. (See Systems

Components chart on page 44.)

CAUTION

If a fastener strips out, you must remove the clip and reposition so the fastener can drill a new

hole at least

3

/

8

" from the stripped hole or install an oversized fastener in the stripped hole.

Failure to do this will result in weakening the roof wind uplift resistance.

INCORRECT

CORRECT

Refer to the chart

on page 44 for

determination of

the proper clip size.

Correct clip size

must be used for

panel system to

function properly.

STEP

4

6. Slide next panel into place and place cap over both panels.

7. After second panel has been set in place, snap Cap over both panels and hand crimp in place (see page 56).

Steps:

1. When installing over rigid insulation, bearing plates must be use at every clip location.

2. Place the panel clip in the groove of the panel rib.

3. Rotate the clip to a vertical position so that the lower tap of the clip rest under the bottom of the panel.

4. Fasten clip to metal deck with (2) #14-13 Deck Screws (length of screws will vary depending on the thickness of the roof

assembly).

5. After installing clips along of the panel, measure across the pan of the panel to confirm panel modularity.

3

/

4

"

Advertising