T-armor, Post hung gutter - floating – Metal Sales T-Armor Series User Manual

Page 57

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice 09/14

57

T-ARMOR

CAUTION

In locations where heavy rainfall or severe ice and

snow may occur, Metal Sales' standard gutters may

not be suitable for use.

INSTALLATION NOTES

All Eave flashings must be installed prior to panel

installation.

1. Install new Eave flashing over top of rigid board

insulation to hold Eave flashing into place, fasten to

substrate at 4'-0" oc.

2. Apply a continuous row of Double Bead Tape Sealant

across the Eave flashing.

3. Install Offset Cleat at Double Bead Tape Sealant

locations and secure with #14-13 Deck Screws at 1'-0" oc.

4. Install the panels by hooking the hemmed edge of the

panel (see 76 for Hemming Instructions) around the end of

the Offset Cleat.

5. Apply Tube Sealant up the side and across the top of the

panel ribs before installing the next panel.

6. Install the Post Hung Gutter by sliding it behind the Eave.

Install the Post Hung Gutter Hanger at 2'-0" oc fastening through the Eave into the roof framing.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of

2" placing two rows of Tube Sealant between the flashings and secure with Pop Rivets, 2.5" oc.

POST HUNG GUTTER - FLOATING

Double Bead Tape Sealant

Eave

Bearing Plate

Panel Clip w/ (2) #14-13 Deck Screws

T-Armor Panel

Fasteners (By others)

Bent Angle (By others)
Rigid Insulation By others)
Metal Decking (By others)

*Panel cap not shown for clarity

Tube Sealant (In panel hem, see page 58)

Tube Sealant (between panel ribs)
#14-13 Deck Screws (1'-0" oc)

Offset Cleat

Moisture Barrier (By others)

1

/

8

"x

3

/

16

" Pop Rivet (1 per Hanger)

Post Hung Gutter
Post Hung Gutter Hanger (2'-0" oc)

1

/

2

:12 Slope

Minimum

9" max

Advertising