T-ARMOR

CAUTION

In locations where heavy rainfall or severe ice and

snow may occur, Metal Sales' standard gutters may

not be suitable for use.

INSTALLATION NOTES

All Eave flashings must be installed prior to panel

installation.

1. Install new Eave Plate over top of rigid board insulation

and fasten through the wood blocking into the metal deck

with #14-13 Deck Screws at 1'-0" oc.

2. Install new Eave flashing on top of the Eave Plate.

3. Apply a continuous row of Double Bead Tape Sealant

across the top of the Eave flashing.

4. Set panel into place and use #12-14

x1

1

/

4

"

Self Driller XL

screws to fasten into place (see page 52).

5. Apply Tube Sealant up the side and across the top of the

panel ribs before installing the next panel.

6. Install the Gutter by sliding it behind the Eave. Install the

Post Hung Gutter Hangers at 2'-0" oc, fastening through

the Eave into the roof framing.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of

2", place two beads of Tube Sealant between the flashings and secure with Pop Rivets, 2.5" oc.

POST HUNG GUTTER - FIXED

Eave

Eave Plate

T-Armor Panel

Bearing Plate

Clip w/ (2) #14-13 Deck Screws

#14-13 Deck Screw (1'-0" oc)

#12-14x1

1

/

4

" SD XL (See Pg 52)

#10-14x1

1

/

2

" Wood Screw XL (1 per hanger)

Double Bead Tape Sealant

Tube Sealant (between panel ribs)

Moisture Barrier (By others)

1

/

8

"x

3

/

16

" Pop Rivet (1 per Hanger)

Post Hung Gutter
Post Hung Gutter Hanger (2'-0" oc)

1

/

2

:12 Slope

Minimum

Wood Blocking
Metal Decking (By others)

Additional #14-13 Deck

Screws may be required for

areas with large snow loads

*Panel cap not shown for clarity

9" max