T-ARMOR

SECTION PROPERTIES AND LOAD TABLES

12", 16", 18", or 24" Coverage

(Flat Shown)

.10"

3"

C

1. Section properties and allowable loads are caculated per Aluminum Design Manual, 2010 Edition.

2. Allowable loads are calculated considering bending, shear, combined bending and shear and deflection.

3. Allowable load calculations do not include consideration for web crippling, fastener / connection limitations or uplift testing.

4. Allowable loads do not include a 1/3 stress increase in uplift.

ALUMINUM SECTION PROPERTIES

ALLOWABLE UNIFORM LOADS psf

(3 or More Equal Spans)

Width

in

Yield

ksi

Weight

psf

I

in

4

/ft

S

TOP

in

3

/ft

S

BOT

in

3

/ft

3'

4'

5'

6'

7'

8'

3'

4'

5'

6'

7'

8'

.032"

12

17

0.77

0.8880

0.4313

0.9734

85

49

31

22

16

12 254 158 106 76

57

44

.040"

12

17

0.96

1.1060

0.5374

1.2099

133 76

49

34

25

19 361 224 151 108 81

63

.032"

16

17

0.69

0.7313

0.3319

0.9503

62

35

23

16

12

9

190 117 79

57

42

33

.040"

16

17

0.86

0.9105

0.4135

1.1803

97

55

35

25

18

14 271 168 113 81

61

47

.032"

18

17

0.66

0.6727

0.2977

0.9420

55

31

20

14

10

8

168 104 70

50

38

29

.040"

18

17

0.83

0.8367

0.3709

1.1695

85

48

31

22

16

12 241 150 101 72

54

42

.032"

24

17

0.61

0.5425

0.2275

0.9240

40

23

15

10

8

6

126 78

52

37

28

22

.040"

24

17

0.76

0.6750

0.2833

1.1462

62

36

23

16

12

9

181 112 76

54

41

32

Advertising