© Metal Sales Manufacturing Corporation / Subject to change without notice 09/14

55

T-ARMOR

INSTALLATION OF PANEL (

cont

.)

MECHANICAL SEAMER

HAND CRIMPER

INSTALLING

PANEL CLIP

STEP

8

SEAMING PANELS

Rental or purchase of the T-Armor mechanical seamer and hand crimpers for field seaming are the responsibility

of the installer. Mechanical seamers and hand crimpers can be aquired from:

Developmental Industries

915 Old Highway 45 S.

Corinth, MS 38834

Phone No. (662) 287-6744

www.msseamers.com

Read the field manual that is enclosed in the case with the seamer. The operator should adhere to all instructions for

proper use of the seamer. Failure to follow the required instructions may result in damage to the panel and/or seamer.

Metal Sales will not be responsible for damage incurred by improper use of the seamer.

All panel sidelaps should be seamed with mechanical seamer as soon as possible, after the panels have been installed.

Hand crimping the panel sidelaps 8” at the eave, endlap, and ridge locations of the panel will help keep the panels in

place during normal erection, but will not prevent the panels from being blown off the roof by moderate strong winds.

At endlap conditions, panels must be handcrimped only. Mechanical seaming of panels will cause rib distortion due to

multiple thicknesses along the endlap.

Run sufficient power to the roof to operate the seamer. If the job site is a long distance from the roof or if the roof s large,

consider using a portable generator placed on the roof near the seam.

Do not overload or damage the roof with the generator unit. Be sure to follow OSHA and local electrical codes when

installing generator.

Prior to seaming panels check all seams making sure they are properly engaged. All dirt, debris and excess sealant should

be removed from flat part of panel and seams.