T-ARMOR

UL 263 FIRE RESISTANCE RATING

Metal Roof Deck Panels

Metal Sales Manufacturing Corporation has obtained fire resistance ratings for various products conducted

according to test criteria set forth by 'Underwriters Laboratories' "Standard Fire Tests of Building Construction and

Material" (ANSI/UL 263). This test procedure is identical to ASTM E-119 and NFPA 251.

The fire resistance rating is for the total assembly and not just the external metal panel. Ratings are expressed in

hours and vary depending upon the assemblies.

In general, the test criteria is to evaluate the assembly's ability to continue to support the superimposed loads

and resist the passage of flame, high temperatures, or hot gases which will ignite combustible materials. The test

assemblies are identified by an alpha-numeric design number.

For detail information on specific assemblies and hourly ratings see UL Fire Resistance Directory.

Category

Test Protocol Description

Fire

UL 790

Class A roof covering over noncombustible deck or framing ot with fire

barrier over combustible materials

AsTM E 84

Flame Spread

Structural

UL 580

Class 90 uplift roofs over steel purlins, 5/8" plywood or 22 ga steel deck

AsTM E 1592

Uplift load resistance for a range of thicknesses, widths and heights

AsTM E 1592

Gravity load resistance

AsTM E 330

Load resistance

Water Penetration

TAs 100

Wind Driven Rain, specimen subject to 110 mph wind with 8.8 inches/

hour water spray with no leaks

AAMA 501.1

Water penetration under dynamic prssure

AsTM E 1646

Water penetration of exterior metal roof panel system

AsTM E 331

Water penetration of exterior curtain wall

Air Leakage

AsTM E 1680

Air leakage through exterior metal roof panel system

AsTM E 283

Air leakage through exterior curtian wall

Thermal Movement

Cyclic Movement

Clips and seam progressed through 100,000 two inch movement cycles

Impact

ICC 500

Large missile impact

FEMA 361

Large missle impact

AsTM E 1996

Large missle impact with cyclic wind pressure testing

AsTM E 1886

Large missle impact with cyclic wind pressure testing

TAs 201, 203

Large missle impact with cyclic wind pressure testing

UL 263 F